| Recommendations for the determination of capillary tube size |
 |
Table considers condensing temperature Tc = 45 °C and heat exchanger in capillary..
Increase length 2% per each K of increase of condensing temperature..
|
 |
| TABLE FOR REFRIGERANT R290 (LBP) |
| Capillary tube length (m) |
| QASH |
M |
Capillary tube internal diameter (mm) & Evaporating temperature (°C) |
| 0,6 | 0,7 | 0,8 | 0,9 | 1 | 1,2 | 1,5 |
| kcal/h | kg/h | -30 | -23,3 | -30 | -23,3 | -30 | -23,3 | -30 | -23,3 | -30 | -23,3 | -30 | -23,3 | -30 | -23,3 |
| 150 | 1,76 | 1,55 | 1,62 | 3,59 | 3,76 | | | | | | | | | | |
| 155 | 1,82 | 1,45 | 1,51 | 3,36 | 3,52 | | | | | | | | | | |
| 165 | 1,94 | 1,28 | 1,33 | 2,96 | 3,10 | | | | | | | | | | |
| 175 | 2,05 | 1,14 | 1,18 | 2,63 | 2,75 | | | | | | | | | | |
| 185 | 2,17 | 1,02 | 1,06 | 2,35 | 2,46 | | | | | | | | | | |
| 200 | 2,35 | | | 2,01 | 2,10 | | | | | | | | | | |
| 210 | 2,47 | | | 1,82 | 1,91 | 3,77 | 3,94 | | | | | | | | |
| 220 | 2,58 | | | 1,65 | 1,73 | 3,43 | 3,58 | | | | | | | | |
| 235 | 2,76 | | | 1,45 | 1,52 | 3,00 | 3,13 | | | | | | | | |
| 250 | 2,93 | | | 1,28 | 1,34 | 2,64 | 2,76 | | | | | | | | |
| 265 | 3,11 | | | 1,14 | 1,19 | 2,34 | 2,45 | | | | | | | | |
| 280 | 3,29 | | | 1,02 | 1,07 | 2,10 | 2,19 | | | | | | | | |
| 295 | 3,46 | | | | | 1,88 | 1,97 | 3,60 | 3,76 | | | | | | |
| 315 | 3,70 | | | | | 1,65 | 1,72 | 3,14 | 3,29 | | | | | | |
| 335 | 3,93 | | | | | 1,45 | 1,52 | 2,76 | 2,90 | | | | | | |
| 355 | 4,17 | | | | | 1,29 | 1,35 | 2,45 | 2,58 | | | | | | |
| 375 | 4,40 | | | | | 1,15 | 1,21 | 2,19 | 2,30 | | | | | | |
| 395 | 4,64 | | | | | 1,04 | 1,09 | 1,97 | 2,07 | 3,56 | 3,70 | | | | |
| 420 | 4,93 | | | | | | | 1,73 | 1,82 | 3,13 | 3,26 | | | | |
| 445 | 5,22 | | | | | | | 1,54 | 1,62 | 2,78 | 2,89 | | | | |
| 470 | 5,52 | | | | | | | 1,37 | 1,45 | 2,48 | 2,58 | | | | |
| 500 | 5,87 | | | | | | | 1,21 | 1,28 | 2,18 | 2,27 | | | | |
| 530 | 6,22 | | | | | | | 1,07 | 1,13 | 1,93 | 2,01 | | | | |
| 560 | 6,57 | | | | | | | | | 1,72 | 1,80 | | | | |
| 595 | 6,98 | | | | | | | | | 1,52 | 1,58 | | | | |
| 630 | 7,40 | | | | | | | | | 1,35 | 1,41 | 3,66 | 3,82 | | |
| 670 | 7,87 | | | | | | | | | 1,19 | 1,24 | 3,21 | 3,36 | | |
| 705 | 8,28 | | | | | | | | | 1,07 | 1,11 | 2,88 | 3,02 | | |
| 750 | 8,80 | | | | | | | | | | | 2,53 | 2,65 | | |
| 795 | 9,33 | | | | | | | | | | | 2,24 | 2,34 | | |
| 840 | 9,86 | | | | | | | | | | | 1,99 | 2,08 | | |
| 890 | 10,45 | | | | | | | | | | | 1,76 | 1,84 | | |
| 945 | 11,09 | | | | | | | | | | | 1,55 | 1,63 | | |
| 1000 | 11,74 | | | | | | | | | | | 1,38 | 1,44 | | |
| 1060 | 12,44 | | | | | | | | | | | 1,22 | 1,28 | | |
| 1120 | 13,15 | | | | | | | | | | | 1,09 | 1,14 | 3,77 | 3,89 |
| 1190 | 13,97 | | | | | | | | | | | | | 3,34 | 3,45 |
| 1260 | 14,79 | | | | | | | | | | | | | 2,98 | 3,08 |
| 1335 | 15,67 | | | | | | | | | | | | | 2,65 | 2,74 |
| 1415 | 16,61 | | | | | | | | | | | | | 2,36 | 2,44 |
| 1500 | 17,61 | | | | | | | | | | | | | 2,10 | 2,17 |
|
 |
QASH is the cooling capacity under ASHRAE (LBP) condition corresponding to the indicated mass flow rate M (liquid subcooled down to 32 °C, return gas superheated up to 32 °C)..
The relationship between length and diameter is, approximately: (L / L0) = (D / D0)5,4..
|
|
| |
| |
|
|